Digital Volume Flowmeter (DVM 4500) from KODYS – HADECO, JAPAN( Intraoperative Doppler & Flow Probes)


Intraoperative Handheld Vascular Dopplers


Minidop ES100VX

Bidop ES100V3

Smartdop 45


 

Typical Operative Procedures in Cardiovascular Surgery

  • Coronary Artery Bypass Grafting (CABG)
  • Bypass Surgery of the lower limbs
    (F-F bypass * A-F bypass * F-P bypass )
    F: Femoral artery A:Aorta P: Popliteal artery
  • Abdominal Aortic Aneurysm (AAA)

Applications:

  • To identify and detect the volume of blood flow in the graft.
  • To detect the volume of blood flow in Coronary / Mammary Arteries.
  • To observe the patency of parent vessel after Aortic Aneurysm Clip Surgery.


Probe Configuration recommended for Cardiovascular surgery in DVM 4500 :

Probe with frequency of 10 MHz and diameter of 2mm (Flexible tip )

Tacking Probe with frequency of 10 MHz

Probe Configuration recommended for Cardiovascular surgery in Minidop ES100VX, Bidop ES100V3 &Smartdop45

CRPProbe– 10MHz with Amplifier

Flat Probe with frequency of 8 MHz – 2 Nos

Standard Probe ( 8 MHz )


 



Typical Operative Procedures in Neurosurgery :

  • Cerebral Aneurysm Clip Surgery
  • Bypass Surgery
  • Carotid Endarterectomy
  • Brain Tumour Extirpation
  • Pituitary Tumour extirpation ( Nasally- Transphenoidal )
  • Cerebral Arteriovenous Malformation ( AVM )
  • Dural Arteriovenous Fistula (AVF)
  • Carotid – cavernous Fistula (CCF)

 

Applications:

  • To observe the patency of parent vessel after Aneurysm Clipping Surgery.
  • To assess the trace of Carotid artery in Endoscopic Skull base Endonasal Transphenoidal Surgery and Pituitary Tumour Decompression.


Probe Configuration recommended for Neurosurgery :

Ultrathin Probe with frequency of 20 MHz and diameter of 0.8 mm

Bayonet Probe with frequency of 20 MHz & diameter of 1.2mm(Flexible tip )

Bayonet Probe with frequency of 10 MHz and diameter of 2mm (Flexible tip )

Standard Probe ( 5 MHz )


 



Probe Configuration recommended for Neuro and ENT Skullbase surgery in Minidop ES100VX, Bidop ES100V3 &Smartdop45 :

NRPProbe - 20MHzor10MHz


 


Urosurgery / Sexology / Andrology

  • To Identify the Artery for Varicocele in Microscopic Subinguinal varicose electomy.
  • Penile Study in Sexologist
    Probe Used : 10 MHz / 20 MHz NRP Probe
    Doctors Used : Dr. Rupin Shah, Urosurgeon from Mumbai
    Dr. SatyasreenivasaRao, Sexologist from AP


Plastic Surgery

  • To assess the trace of Perforator flaps
  • To assess the trace of Digital arteries in Anastomosis.
    Probe Used : 10 MHz VRP Probe / 8 MHz Probe
    Doctors Used : Plastic Surgeons in CMC Vellore


Ortho Surgery

  • To trace the arteries in casualties.
  • To trace the arteries which supply blood to the tumours.
    Probe Used : 10 MHz VRP Probe / 8 MHz Probe









Dental Surgery

  • To assess the arteries in Maxillofacial Surgery
    Probe Used : 10 MHz VRP Probe / 8 MHz Probe.








 


Surgical Probes for Minidop ES 100VX, Bidop ES100V3 & Smartdop 45

Amplifier

NRPProbe - 20MHz or 10MHz

CRPProbe– 20MHz or 10MHz

VRPProbe– 10MHz